HPGe and Si(Li) X-ray Spectrometers

HPGe and Si(Li) X-ray Spectrometers
by Princeton Gamma-Tech
 3.0/5.0 (1 review)

Features: • Lithium-drifted silicon (10, 30, 60, or 80 mm2 ) • High-purity germanium (10, 30, 50 or 100 mm2) • Stainless steel endcap with beryllium window of 0.3 or 0.5 mil thickness for Si(Li) • Horizontal unitary cryostat with fixed geometry and conflat flange, 7.5 liter dewar • TR-1 Transistor reset preamplifier • Appropriate bias, signal and power cables • Unlimited ...read more

Request Pricing




Receive your quote directly from Princeton Gamma-Tech for HPGe and Si(Li) X-ray Spectrometers

Princeton Gamma-Tech

Reviews

AVERAGE RATING: 3.0

1 scientist has reviewed this product

Write your own review



  • 2 out of 5EASE OF USE
  • 3 out of 5AFTER SALES SERVICE
  • 4 out of 5VALUE FOR MONEY

Melinda Stephens


Status:


See all reviews
Member since 2003

Organization:
Geneva College
Read more »
RATING: 3.0

  • 2 out of 5EASE OF USE
  • 3 out of 5AFTER SALES SERVICE
  • 4 out of 5VALUE FOR MONEY




Review date: 19 Mar 2003

HPGe and Si(Li) X-ray Spectrometers

"Considering its aging qualites it has performed decently for quite a number of years. Now my company has decided to use the newer model."

Description

 

Features:

• Lithium-drifted silicon (10, 30, 60, or 80 mm2 )
• High-purity germanium (10, 30, 50 or 100 mm2)
• Stainless steel endcap with beryllium window of 0.3 or 0.5 mil thickness for Si(Li)
• Horizontal unitary cryostat with fixed geometry and conflat flange, 7.5 liter dewar
• TR-1 Transistor reset preamplifier
• Appropriate bias, signal and power cables
• Unlimited temperature cycling without loss of resolution
• HV cut-off circuitry


Options:

• Variable position (DS) cryostat with manual or motorized slide
• JT Cool cryocooler with convenient stand for all-attitude, LN2-free operation
• Bellows vacuum seal
• High-angle entry configurations; custom configurations for unique applications
• 15-liter dewar
• Thin windows for light element detection
• Low-microphonic crystal mounting

PGT manufactures both Si(Li) and HPGe detectors for X-ray analysis. Si(Li) detectors with the standard beryllium window have a useful energy range of 1-60 keV, while HPGe detectors are suitable up to 100 keV. Optional light-element capability extends the lower limit to below 200 eV. Both HPGe and Si(Li) detectors are fully temperature-cyclable and may be stored for long periods at room temperature with no degradation in resolution.

The X-ray source can range from nuclear accelerators to secondary X rays generated by fluorescence. X-ray detectors are used extensively for research, quality control, and failure analysis. These detectors are also interfaced with scanning electron microscopes for simultaneous qualitative and quantitative microanalysis of elements from boron through uranium by energy-dispersive spectroscopy.

Product Overview

HPGe and Si(Li) X-ray Spectrometers by Princeton Gamma-Tech
HPGe and Si(Li) X-ray Spectrometers




  • 2out of 5EASE OF USE
  • 3 out of 5AFTER SALES SERVICE
  • 4 out of 5VALUE FOR MONEY





Request Pricing

SelectScience Trusted Banner
Why make an inquiry with SelectScience?

Advertisement

Advertisement