Quantitation of Human Plasma and Breast Milk Thiamine Monophosphate (TMP) and Thiamine by Applying Impact™ Protein Precipitation Plate Technology with Gemini® 3 μm NX-C18 HPLC Columns
23 Dec 2014

Thiamine monophosphate (TMP) and thiamine were extracted from human plasma and human breast milk by performing a rapid protein precipitation using Impact Protein Precipitation Plates followed by HPLC analysis using a Gemini 3 μm NX-C18 100 x 3.0 mm HPLC column with fluorescence detection. Impact technology offers easy, fast protein removal while providing maximized recovery of the target analytes. The Gemini 3 μm NX-C18 HPLC column produced excellent chromatographic resolution, sensitivity, and high peak capacities.

Show    per page
1 of 2     Page  1 2 Next 
Fast, Accurate and Reproducible Method for Simultaneous Quantitation of Pyridoxal 5’-phosphate and Pyridoxic Acid in Human Plasma by HPLC with Fluorescent Detection HPLC method development, molecular diagnostics17 Dec 2014Read
Rapid and Effective Cleanup of Vitamin D2 and D3 from Human Plasma Using Phree™ Phospholipid Removal Plates and Kinetex® Core-Shell HPLC/UHPLC Columns HPLC method development, vitamin d12 Dec 2014Read
Simple and Fast Quantitation of Nicotinic Acid and Nicotinamide in Human Plasma by Applying Impact™ Protein Precipitation Plate Technology with Gemini® 3 μm C18 HPLC Columns protein analysis, HPLC method development, human plasma9 Dec 2014Read
Extraction of Total Cortisol from Human Plasma Using Novum™ Simplified Liquid Extraction (SLE) 96-Well Plates cortisol, human plasma5 Dec 2014Read
Extraction and LC/MS Analysis of Oligonucleotide Therapeutics from Biological Matrices Using Clarity® OTX™ SPE and Clarity Oligo-MS™ HPLC/UHPLC Columns oligos, solid phase extraction, Mass Spectrometry1 Dec 2014Read
Effective Sample Preparation and Rapid LC/MS/MS Analysis of a Large Pain Panel Screen Using Phenomenex Columns urine analysis, HPLC method development, solid phase extraction24 Nov 2014Read
A Novel Dried Matrix Microsampling Device that Eliminates the Volume Based Hematocrit Bias Associated with DBS Sub-punch Workflows hematology solutions, dried blood spots21 Nov 2014Read
Extraction Guidelines for the Mitra™ (RUO) Microsampling Device hematology solutions, blood analysis19 Nov 2014Read
Removal of Beta-Glucuronidase Enzyme from Urine Post-Hydrolysis to Improve Assay Performance and Column Lifetime urine analysis, high throughput, enzymes14 Nov 2014Read
Using Longer Aeris™ PEPTIDE Core-Shell HPLC/UHPLC Columns for Improved Peptide Mapping protein analysis, peptide mapping11 Nov 2014Read

Popular tags in SelectScience