Using Analyte Protectants and Solvent Selection to Maximize the Stability of Organophosphorous Pesticides during GC/MS Analysis
28 May 2013

This application note evaluates the stability of a number of organophosphorous pesticide residues in several solvents, resulting in the selection of an optimal solvent. It also evaluates the positive effect of several analyte protectants on the recoveries of organophosphorous pesticides during GC/MS analysis using the Agilent 7890A Series GC. Results show that hexane provides the best analyte stability for a wide range of organophosphorous pesticides, and d-sorbitol provided the most consistent improvement in recovery as an analyte protectant.

Show    per page
1 of 18     Page  1 2 3  ... Next 
EPA Method 522: Determination of Selected Organic Contaminants by Agilent Model 240 GC/MS/MS EPA methods, environmental contamination, dioxane24 May 2013Read
Environmental Volatiles Using an Agilent 7697A Headspace Sampler, an Agilent 7890B GC, and an Agilent 5977A Series GC/MSD water analysis, volatiles, environmental contamination23 May 2013Read
Analysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sample with the Agilent 7890B Gas Chromatograph solvent monitoring, chromatography method development, headspace sampler23 May 2013Read
Sensitive LC/MS Quantitation of Trace Organic Contaminants in Water with Online SPE Enrichment EPA methods, water analysis, trace level impurities20 May 2013Read
HaloPlex Target Enrichment from FFPE Tissues DNA extraction, target-enrichment, FFPE extraction20 May 2013Read
Determination of Semivolatile Organic Compounds in Drinking Water Using the Agilent 5977A Series GC/MSD environmental contamination, semi volatile organic compounds17 May 2013Read
High-Resolution Oligonucleotide-Based aCGH Analysis of Single Cells in Under 24 Hours cancer, copy number variation, genomic hybridization16 May 2013Read
Quantification of Trace-level Herbicides in Drinking Water by Online Enrichment with the Agilent 1200 Infinity Series Online-SPE Solution and Triple Quadrupole MS Detection drinking water analysis, triple quadrupole MS, environmental contamination15 May 2013Read
High Resolution Glycopeptide Mapping of EPO using an Agilent AdvanceBio Peptide Mapping Column peptides, peptide mapping, glycoprotein13 May 2013Read
Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS peptides, peptide mapping, HILIC13 May 2013Read

Popular tags in SelectScience

Buying guides

Write a Review

Join 200,000 Scientists Online

Become a member for FREE access to:

  • 250,000 full product and supplier listings
  • 10,000 user reviews and comments
  • Daily news and videos
  • 2,500 application notes and videos
  • 2,000 of the best jobs in Science

Don't miss out!

Join The Community Today