Veriti® thermal cycler by Thermo Fisher Scientific Invitrogen

3.8
/
5.0
  |  7 reviews
The Veriti® Thermal Cycler delivers the proven reliability you expect from Applied Biosystems® PCR machines with the added control of VeriFlex™ Blocks. With Veriflex™ Blocks, you have six independent temperature blocks providing precise control over your PCR optimization, providing “better than gradient” functionality.Additionally, the powerful user interface, presented on a color touch screen, simplifies the setup and use of the Veriti™ 96-Well Fast Thermal Cycler. Optional setups for fast PCR... Read more
The supplier does not provide quotations for this product through SelectScience. Browse these related products instead


Veriti® thermal cycler by Thermo Fisher Scientific Invitrogen product image
Veriti® thermal cycler



Average Rating: 3.8
7 Scientists have reviewed this product

4 out of 5
Ease of use
4 out of 5
After sales service
4 out of 5
Value for money


  • Status:

    Reviewer
  • Member since: 2014

  • Organization: OHSU



  • Ease of use
    4 out of 5
    After sales service
    1 out of 5
    Value for money
    1 out of 5
Share this Review on LinkedinShare this Review on TwitterShare this Review on Facebook
Rating: 2.0

  • Application Area: Routine PCR, NGS

"We bought this thermal cycler July 2011. We are a small lab and use it rarely. It broke yesterday and problems are in its cover heating system. Never see a poor quality thermal cycler like this! "

Review date: 09 Oct 2014 | Veriti® thermal cycler
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: Westmead Millennium Institute



  • Ease of use
    3 out of 5
    After sales service
    2 out of 5
    Value for money
    3 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 2.7

  • Application Area:PCR

"We have three of these machines in the lab that are used several times each day. The machines perform the cycles well, and the results indicate that the protocols are working on them. There is one key drawback to this machine, which is that the cover remains at 50 C when the machine is idle or set at 4 C for infinity. Therefore, you cannot leave plates in it to run overnight because they won't cool all the way down and because of concerns of wear on the machine. Additionally, these machines are louder and slower than other PCR machines in the lab. We are heavy PCR machine users, and these machines are not up to the task. I would not recommend this machine to other researchers."

Review date: 14 Apr 2014 | Veriti® thermal cycler

Manufacturer's Response

Hi Kirston,

Thank you for your comments. You are correct that in your assessment of Veriti that when the block is programmed to do a sub-ambient (cold) temperature, the lid temperature defaults to 50C. This is true unless you set the heated lid temperature default setting to “off” where it will maintain “ambient temperature” (the temperature of your outside environment) for the entirety of your run. However, we don’t recommend you turn off the heated lid due to the possibility of evaporation when the block heats up. Let me clear up a few misconceptions underlying your comments:

1. The temperature of the lid does not significantly affect the temperature of the sample provided you are running within the specified volume range (10-80ul). It only serves to reduce evaporation in the case of hotter temperatures, or to reduce condensation at the top of the tube in the case of cooling. Our temperature accuracy specification for your sample is +/- 0.25C, which means that your sample will always be within 0.25C of the programmed set point, regardless of lid temperature.

2. We have done reliability testing with Veriti at 4C in adverse environmental conditions (high humidity, and ambient temperatures) for 72 hours. This means that you can confidently leave your samples in the machine on a Friday afternoon, and pick them up on Monday morning with no adverse effects. Using the instrument at a 4C hold on the instrument does not reduce the reliability of the instrument.

I hope that your Veriti continues to provide you quality PCR product for years to come. We are sure it will. Best of luck in your future experiments.
  • Status:

    Reviewer

  • Member since: 2009

  • Organization: kgmu



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.7

  • Application Area:Human Molecular Genetics

"This is the first time I have fallen in love with an instrument in my lab. It is excellent. "

Review date: 25 Feb 2014 | Veriti® thermal cycler
  • Status:

    Reviewer

  • Member since: 2012

  • Organization: Cold Spring Harbor Laboratory



  • Ease of use
    4 out of 5
    After sales service
    4 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.0

  • Application Area:PCR

"This machine has lots of extra features including multiple annealing temperature settings. However, the computer is slow so there is a lag between changing steps. Altogether, it's a good machine for routine PCR reactions."

Review date: 19 Feb 2013 | Veriti® thermal cycler
  • Status:

    Reviewer

  • Member since: 2009

  • Organization: UNIVERSITY OF HOUSTON



  • Ease of use
    5 out of 5
    After sales service
    4 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.7
"Good one to use."

Review date: 10 Aug 2011 | Veriti® thermal cycler
  • Status:

    Reviewer

  • Member since: 2010

  • Organization: Saskatchewan Research Council



  • Ease of use
    4 out of 5
    After sales service
    4 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.0
"These are great reliable instruments with fantastic service from Applied Biosystems."

Review date: 08 Feb 2010 | Veriti® thermal cycler
  • Status:

    Reviewer

  • Member since: 2010

  • Organization: Saskatchewan Research Council



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.7
"A great, easy-to-use machine."

Review date: 04 Feb 2010 | Veriti® thermal cycler
The Veriti® Thermal Cycler delivers the proven reliability you expect from Applied Biosystems® PCR machines with the added control of VeriFlex™ Blocks.

With Veriflex™ Blocks, you have six independent temperature blocks providing precise control over your PCR optimization, providing “better than gradient” functionality.

Additionally, the powerful user interface, presented on a color touch screen, simplifies the setup and use of the Veriti™ 96-Well Fast Thermal Cycler. Optional setups for fast PCR or standard PCR methods provide you the flexibility to shorten your PCR cycling time.

Veriti® Thermal Cycler Features & Benefits:

  • PCR optimization - each block can be set with a specific temperature, which is ideal for precise control over PCR optimization.
  • Run more experiments - the six Peltier blocks can also be used to run up to six different annealing temperatures in the same run.
  • Use the on-board Tm calculator to approximate the optimal annealing temperature.
  • Run up to six separate temperatures in the same plate to determine the optimal annealing temperature.
  • VeriFlex™ Blocks maintain their thermal characteristics between optimizing and isothermal conditions, eliminating the need for further optimization steps.
  • Run up to six different annealing temperatures for cycle sequencing or endpoint PCR.
  • Incubate samples at six different temperatures simultaneously.

Product Overview

Veriti® thermal cycler by Thermo Fisher Scientific Invitrogen product image

Veriti® thermal cycler

Manufacturer Thermo Fisher Scientific Invitrogen

3.8 / 5.0 | 7 reviews