ultrafleXtreme™

Attain the highest level of mass spectrometry performance with the ultrafleXtreme™, an instrument exceeding all your expectations. The new ultrafleXtreme™ incorporates next-generation MALDI-TOF and TOF/TOF technology. Combining true 1kHz speed in both TOF and TOF/TOF modes with ultrahigh performance and extreme flexibility for a broad variety of complementary research, clinical and applied proteomics applications.ultrafleXtreme™ Features: Innovative smartbeam-II™ laser enables ultra-high data acquisition speed in both MS and MS/MS at full systems performance. Laser focus diameters down to 10 µm for high spatial resolution imaging without pixel overlap. Mass resolving power up to 40,000 and 1 ppm mass accuracy for highest confidence. Unique laser-irradiation self-cleaning Ion S...Read more

Receive your quote directly from Bruker Daltonics for ultrafleXtreme™

Reviews

8 Scientists have reviewed this product


Write your own review

Average Rating: 4.3

Ease of use
5 out of 5
After sales service
4 out of 5
Value for money
4 out of 5
Rating: 4.7
Ease of use
5 out of 5
After sales service
5 out of 5
Value for money
4 out of 5
  • Review date: 28 Apr 2015

  • Application Area: The product is best suited for imaging purpose in metabolomics and proteomics.

  • ultrafleXtreme™

"UltrafleXtreme is well suited for imaging and profiling of large biomolecules especially lipids, peptides and proteins. The instrument is easy to operate with detailed instructions in manual, robust and stable. The software is user friendly. Service after sale is very good. For European countries, service can be provided almost right away. Technicians from company can observe and check out the instrument via internet. Generally, this instrument is excellent for routine analyses in metabolomics and proteomics with spatial resolution of imaging not better than 20 micrometer."

Rating: 4.0
Ease of use
5 out of 5
After sales service
3 out of 5
Value for money
4 out of 5
  • Review date:31 Mar 2015

  • Application Area:Protemic & Glycomics reserarch

  • ultrafleXtreme™

"Very user friendly with a multipurpose interface. Can be used for peptides and proteins with extreme ease and reproducibility. Many user friendly options available for making it an easy to use machine. After sales care is ok and not up to the mark with a weak after sales service support. The machine is very robust and truly value for money. Overall the system is best suited for proteomics application. "
Rating: 4.0
Ease of use
5 out of 5
After sales service
3 out of 5
Value for money
4 out of 5
  • Review date:22 Apr 2014

  • Application Area:Small Molecules

  • ultrafleXtreme™

"Bruker Utraflex MALDI-TOF/TOF-MS series are primarily designed for Proteomics application. It’s an outstanding easy to use instrument that works very stable for years long without significant problems and doesn't require many consumables. Flex analysis software generally required few minutes training to enable user to start acquiring spectra. Apart from Proteomics one by knowing the basics of LDI and TOF analyzers, can use instrument for the analysis of small molecules with extremely high throughput. Especially such instrument can be applied for species finger printing purposes with and without matrix approaches. It can deliver very sensitive and accurate measurements for small molecule if calibrated correctly. People working in areas like matrix development, matrix free LDI, solution free LDI can try many different options to efficiently ionize the molecules of interest but such application required advance knowledge of instrument design which is generally not given out by vendors! "
Rating: 4.3
Ease of use
4 out of 5
After sales service
5 out of 5
Value for money
4 out of 5
  • Review date:11 Feb 2011

  • ultrafleXtreme™

"Excellent accuracy and sensitivity. Good for ordinary and imaging mass spectroscopy. But the software needs to provide more parameters and control."

Description

Attain the highest level of mass spectrometry performance with the ultrafleXtreme™, an instrument exceeding all your expectations.

The new ultrafleXtreme™ incorporates next-generation MALDI-TOF and TOF/TOF technology. Combining true 1kHz speed in both TOF and TOF/TOF modes with ultrahigh performance and extreme flexibility for a broad variety of complementary research, clinical and applied proteomics applications.

ultrafleXtreme™ Features:

  • Innovative smartbeam-II™ laser enables ultra-high data acquisition speed in both MS and MS/MS at full systems performance.
  • Laser focus diameters down to 10 µm for high spatial resolution imaging without pixel overlap.
  • Mass resolving power up to 40,000 and 1 ppm mass accuracy for highest confidence.
  • Unique laser-irradiation self-cleaning Ion Source ensures robust, long-term highest-performance operation.
  • The high efficiency and sensitivity of the LID-LIFT process delivers MS/MS spectra with nominal mass resolution for peptides.

Product Overview

Product Image

ultrafleXtreme™

by Bruker Daltonics

4.3/5.0 (8 reviews)
Ease of use
5 out of 5
After sales service
4 out of 5
Value for money
4 out of 5






Receive your quote directly from Bruker Daltonics for ultrafleXtreme™