Incorporates PPC for enhanced ease-of-use, functionality and performance in an automated sample-tube handling system for unattended analysis of up to 50 samples. Concurrent desorption of the next sample while the current sample is undergoing GC analysis optimizes productivity. Also incorporates loading of internal standard into clean tubes to provide sample-integrity validation and to improve precision (repeatability) of the analysis.
Allows the ability to condition tubes during chromatography to minimize downtime and enhance productivity and also includes separate trap clean and test function, which saves time and protects the GC column and detector. Also incorporates the ability to re-collect sample for repeat analysis, the ability to perform dry purge without the internal standard accessory and the ability to perform tube and trap impedance measurement as a diagnostic of system performance. Provides truly outstanding analytical performance in an automated sample-tube handling system for unattended analysis of up to 50 samples.
Application notes and news
- The Determination of Low Level Benzene, Toluene, Ethyl Benzene, and Xylenes (BTEX) in Drinking Water by Hea...
- Breakthroughs in Technology Help CARO Analytical Services Capture Major Share of the Western Canadian Soil ...
- Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investiga...
- Ozone Precursor Analysis Using a Thermal Desorption-GC System
- Measuring Environmental Volatile Organic Compounds by U.S. EPS Method 8260B with Headspace Trap GC/MS
- Increasing Sample Throughput in Method 8260 Using the Novel Oven Design of Clarus 600 GC/MS
- Analysis of Fuel Oxygenates by U.S. EPA Method 8260B Using Headspace Trap with GC/MS
- Ozone Precursor Analysis Using the TurboMatrix Thermal Desorption GC System
- Thermal Desorption-GC/MS Analysis of Polycyclic Aromatic Hydrocarbons on Fine Particulates in Air
- The Determination of 2,4,6-Trichloroanisole in Wine using Headspace Trap with GC/MS
- Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investiga...
- US EPA Volatile Organics Method 524.2 Using Purge and Trap GC/Mass Spectroscopy
- Application of Thermal Desorption to Occupational Exposure Monitoring