SPE-DEX® 4790 Extractor System

The SPE-DEX 4790® Automated Extraction System is a fully automated sample preparation system designed to rapidly process samples for trace level analysis of organic chemical contaminants from aqueous samples using EPA Methods for Solid Phase Extraction (SPE). Analytical Laboratories are pressed to provide the best turnaround time with economy and accuracy. The Horizon Technology SPE-DEX® 4790 Extractor can help by providing rapid, reproducible extraction of semivolatile organics from liquids, getting a better-prepared sample to the chromatograph faster.Although much progress has been made in improving the analysis step, the sample preparation step can still be improved. The Horizon Technology SPE-DEX 4790 Extractor provides a combination of factors help to speed extraction of semi-volat...Read more

Receive your quote directly from Horizon Technology, Inc..

Reviews

5 Scientists have reviewed this product


Write your own review

Average Rating: 3.8

Ease of use
4 out of 5
After sales service
4 out of 5
Value for money
4 out of 5
Rating: 4.7
Ease of use
5 out of 5
After sales service
4 out of 5
Value for money
5 out of 5
  • Review date: 23 May 2014

  • Application Area: Organic -EPA 525.2

  • SPE-DEX® 4790 Extractor System

"I like the SPE-DEX 4790 automated extraction system. It is a fully automated sample preparation system. It is using less solvent consumption and sample run times are less. You can extract with unattended analyst. It is easy to use. The software is very easy to use too. The SPE-DEX 4790 extractor is the best instrument than any automated extractor manufacturers so far."

Rating: 3.7
Ease of use
5 out of 5
After sales service
3 out of 5
Value for money
3 out of 5
  • Review date:23 May 2014

  • Application Area:Environmental

  • SPE-DEX® 4790 Extractor System

"I think the extractor is easy to use but the extractor is priced too high. I would recommend this product but not without saying the extractor has not been updated in a long time. The design could be a lot better."
Rating: 4.0
Ease of use
4 out of 5
After sales service
4 out of 5
Value for money
4 out of 5
  • Review date:23 May 2014

  • Application Area:SOC Primary C8 Disk Extractor

  • SPE-DEX® 4790 Extractor System

"This has been our primary extractor for EPA Method 525.2, UCMR2 EPA Method 525.2 and 529, and UCMR3 EPA Method 539.It performs well for all C8 disks and most cartridges. Over the past 6 years, this product has saved our company for hiring an additional extraction tech."
Rating: 4.0
Ease of use
4 out of 5
After sales service
4 out of 5
Value for money
4 out of 5
  • Review date:23 May 2014

  • Application Area:Environmental- Drinking Water Testing

  • SPE-DEX® 4790 Extractor System

"The system has worked out great. The analyst set up the samples and let the system do most of the work. Get consistent flows and results."

Description

The SPE-DEX 4790® Automated Extraction System is a fully automated sample preparation system designed to rapidly process samples for trace level analysis of organic chemical contaminants from aqueous samples using EPA Methods for Solid Phase Extraction (SPE).

Analytical Laboratories are pressed to provide the best turnaround time with economy and accuracy. The Horizon Technology SPE-DEX® 4790 Extractor can help by providing rapid, reproducible extraction of semivolatile organics from liquids, getting a better-prepared sample to the chromatograph faster.

Although much progress has been made in improving the analysis step, the sample preparation step can still be improved. The Horizon Technology SPE-DEX 4790 Extractor provides a combination of factors help to speed extraction of semi-volatiles from water. The system is automated, requiring less attention and more providing a more reproducible process. The second important factor is the use of solid phase extraction (SPE) to collect and elute the analytes, reducing the extraction time and solvent usage.

The SPE-DEX® 4790 Extraction System uses Solid Phase Extraction (SPE) technology to replace the old, labor-intensive liquid-liquid extraction (LLE) technique. In addition to delivering accurate, more consistent results, SPE technology slashes both sample processing times and solvent use.

Solvent consumption is cut by up to 90% compared to traditional liquid-liquid extraction methods. Sample run times are less than 5 minutes.

Unattended operation increases the overall productivity of your lab as personnel are freed up for other projects. Plus variability between chemists' techniques is eliminated. The SPE-DEX® 4790 Extractor processes samples directly from the original sample bottle. It automatically delivers all solvents, regulates sample processing and disk drying times, rinses the sample bottle and collects the extract.


The SPE-DEX® 4790 Extraction System features:

  • Bench-top operation frees up valuable hood space
  • Modular design allows for addition of up to seven extraction stations
  • Interchangeable 47mm, 50mm, 90mm SPE disk holders
  • Handles sample volumes from 20ml to 4L

Product Overview

Product Image

SPE-DEX® 4790 Extractor System

by Horizon Technology, Inc.

3.8/5.0 (5 reviews)
Ease of use
4 out of 5
After sales service
4 out of 5
Value for money
4 out of 5






Receive your quote directly from Horizon Technology, Inc. for SPE-DEX® 4790 Extractor System