Patchliner by Nanion Technologies GmbH

Manufacturer Nanion Technologies GmbH  |  Available Worldwide
4.9
/
5.0
  |  6 reviews
The Patchliner is a fully automated patch clamp system which records from either 4 or 8 cells simultaneously. The HEKA EPC10 amplifiers, full control over the pipette speed, ability to change protocols on-the-fly and flexible add-ons for temperature control and dynamic clamp make this instrument the most versatile APC system on the market. 


Patchliner by Nanion Technologies GmbH product image
Patchliner
Buy Now

Place your order directly with the manufacturer.




Average Rating: 4.9
6 Scientists have reviewed this product

5 out of 5
Ease of use
5 out of 5
After sales service
5 out of 5
Value for money


  • Status:

    Reviewer
  • Member since: 2022

  • Organization: Universitat Rovira i Virgili



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this Review on LinkedinShare this Review on TwitterShare this Review on Facebook
Electrophysiology is a no brainer with the Patchliner
Rating: 5.0

  • Application Area: Detection of marine toxins acting on ion channels

"After years of working in neuropharmacology but far away from electrophysiology, we have had the opportunity to use the Patchliner. Our equipment is living a second life after 5 years in a box and after some software upgrades, it's alive and kicking! We only followed a day and a half of tailored formation at Nanion facilities in Munich and after 3 days we are having high-quality results, high productivity, and concentration-response curves after three mouse clicks! Just prepare the drug solutions and the suspension of cells and after 10 min you will get 6-8 concentration-response curves with their IC50 values automatically! Amazing! The patch liner is robust, reliable, and flexible. However, great equipment is nothing without support. We have received high-quality remote technical assistance that has solved all the small issues inherent to a new setup in a different lab and, most importantly, specific, high-quality scientific advice on which cells to use, what configuration to set up, experiment designs, and application notes, etc. A five stars team, because first of all, they are scientists and have a fair idea of what you need: electrophysiology without all the hassle."

Review date: 23 May 2022 | Patchliner
  • Status:

    Reviewer

  • Member since: 2020

  • Organization: University of Szeged, Hungary



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Excellent tool for ion channel assays and screening.
Rating: 5.0

  • Application Area:Ion channel recording and screening

"The Patchliner is a fully automated medium throughput planar patch clamp device with integrated temperature control. Besides the reliable and easy-to-use instrument, the experienced team at Nanion provide continuous support and technical background to develop the experimental methods and achieve the best quality records. Highly recommendable technology and platform for ion channel recordings and screening."

Review date: 18 Oct 2020 | Patchliner
  • Status:

    Reviewer

  • Member since: 2020

  • Organization: The Florey Institute of Neuroscience and Mental Health



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
An amazingly versatile platform for all your electrophysiological needs.
Rating: 5.0

  • Application Area:Ion channels and human diseases

"Our research focuses on understanding the pathology of ion channel disorders, using in vitro and in vivo electrophysiology to reveal opportunities for developing novel therapies. In particular, our research focuses on ion channel gene mutations that cause epilepsy. Patchliner has been an invaluable tool enabling us to examine ion channels both endogenously and exogenously expressed by a variety of different cell types, including mammalian cell lines as well as primary cells. The system allows us to examine the effects of different mutations and different compounds on the biophysical properties of a variety of ion channels, including sodium, potassium and calcium, to mention a few. Patchliner produces high fidelity, reproducible data which is very comparable to that produced using conventional techniques. It is easy to use and throughput is an attractive bonus. The systems temperature control is a really great feature for temperature sensitive channels. The after sales service from this company is second to none."

Review date: 03 Jun 2020 | Patchliner
  • Status:

    Reviewer

  • Member since: 2020

  • Organization: Bionomics Ltd, Australia



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Flexible research tool and screening workhorse for ion channels.
Rating: 5.0

  • Application Area:Drug discovery

"Patchliner is an automated, single pipette, 8 parallel-channel system. It comes with many, easily modifiable, protocols for all ion channels groups. I have used Patchliners for primary, secondary and selectivity screens in voltage and ligand gated ion channel programs. The quality of the recordings is comparable to the manual patching, even for fast ligand gated channels such as alpha 7 nicotinic acetylcholine receptor. The technical support from Nanion is excellent. Love it."

Review date: 12 Jan 2020 | Patchliner
  • Status:

    Reviewer

  • Member since: 2020

  • Organization: Philip Morris Products SA



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Overall the Patchliner is a high quality machine supported by high quality people!
Rating: 5.0

  • Application Area:Ion channel pharmacology

"The Patchliner comes with robust and high quality Heka amplifiers. Therefore a previous knowledge of the Heka software is clearly helpful. Nevertheless, for the people that are not familiar with the Heka software, Nanion Patchliner created their own software, with a more friendly user interface, to control the Heka commands. Overall it is easy to use. The Patchliner offers the possibility to measure up to 8 cells simultaneously (some cells are "easier" than other though and the success rate can vary accordingly). The solutions are directly applied by the Patchliner "Syringe Pipettor". The speed of the solution application can be modified and the protocols are very flexible and easy to set up. Results are very reproducible. It allows the recording of all types of ion channels (including mechanosensitive channels!). In addition, the Patchliner support team is incredible to help you anytime you need in a very short notice!"

Review date: 10 Jan 2020 | Patchliner
  • Status:

    Reviewer

  • Member since: 2019

  • Organization: Apconix



  • Ease of use
    4 out of 5
    After sales service
    5 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Fantastic team and equipment.
Rating: 4.3

  • Application Area:Ion channel electrophysiology

"Exceptional after sale care from the team at Nanion. Always available for an email or call. Always happy to do traning and help new members of the team learn how to use complex software."

Review date: 22 Nov 2019 | Patchliner

The Patchliner is versatile yet robust, ideal for basic research of ion channel biophysics and mechanisms of action, sophisticated assays such as heat activation, right through to routine assays such as safety screening of hERG or other cardiac ion channels in accordance with the CiPA initiative.

The Patchliner is a medium throughput automated patch clamp system which comes as a 4 or 8 channel version. Experimental protocols are programmed using the PatchControlHT software which controls the Tecan robot for addition of solutions, cells and compounds, and controls the PatchMaster software for data acquisition. NPC-16 chips, the consumable for the Patchliner, can be loaded on the chip wagon and the instrument can run unattended for 48 recordings.

Features include: 

  • External & internal solution exchange
  • Unlimited compound applications due to continuous waste removal
  • Temperature Control
  • Voltage & current clamp mode
  • Dynamic clamp
  • Single- and multihole chips
  • Rseries compensation
  • Minimized cell consumption option

Applications:

  • Voltage and ligand-gated ion channel analysis
  • Temperature-activated channel analysis
  • Intracellular-activated ion channel analysis
  • Whole-cell & perforated patch clamp mode
  • Suitable for cell lines, primary cells and stem cells

Product Overview

Patchliner by Nanion Technologies GmbH product image

Patchliner

Manufacturer Nanion Technologies GmbH  |  Available Worldwide

4.9 / 5.0 | 6 reviews