For Determination of Trace Perchlorate Using Suppressed Conductivity Detection. The IonPac® AS20 hydroxide-selective anion-exchange column is specifically designed for determination of trace concentrations of perchlorate in drinking water, surface water, and groundwater matrices. The capacity and selectivity of the AS20 ensures that perchlorate can be quantified at low μg/L concentrations using suppressed conductivity detection, even in the presence of very high concentrations of chloride, carb... Read more


Thermo Scientific™ IonPac® AS20 Hydroxide-Selective Anion-Exchange Column by Thermo Fisher Scientific product image
Thermo Scientific™ IonPac® AS20 Hydroxide-Selective Anion-Exchange Column


0 Scientists have reviewed this product


Write the First Review

No Reviews

For Determination of Trace Perchlorate Using Suppressed Conductivity Detection.

The IonPac® AS20 hydroxide-selective anion-exchange column is specifically designed for determination of trace concentrations of perchlorate in drinking water, surface water, and groundwater matrices. The capacity and selectivity of the AS20 ensures that perchlorate can be quantified at low μg/L concentrations using suppressed conductivity detection, even in the presence of very high concentrations of chloride, carbonate, and sulfate.

The new IonPac AS20 Capillary Column is packed with the same material as the equivalent standard bore version (providing the same performance as a 4 mm column) but requires only 1/100th the eluent flow rate. The capillary format provides the advantage of significantly reduced eluent consumption, which helps reduce operating costs.


IonPac® AS20 Hydroxide-Selective Anion-Exchange Column Features:

  • Recommended for US EPA Method 314.1 (Confirmatory Method)
  • High capacity: 310 μeq per column. (4 × 250 mm)
  • Use the Cryptand C1 Concentrator Column for sample preconcentration with the analytical column
  • Simplified Reagent-Free IC operation provided by the Eluent Generator
  • ASRS 300 or ACES 300 provides RFIC operation with low background and enhanced analyte sensitivity
  • Column selectivity is optimized for 30 °C operating temperature
  • Compatible with organic solvents

Column Details:

  • Bead Size: 7.5 µm
  • Pore Size: 2000 Å
  • Length: 250 mm
  • ID: 0.4, 2.0, 4.0