Infinite® M1000 PRO multimode microplate reader by Tecan

Manufacturer Tecan
4.4
/
5.0
  |  30 reviews
The Infinite M1000 PRO premium multimode microplate reader offers maximum versatility and sensitivity for demanding drug discovery, assay development and life sciences research applications.


Infinite<sup>®</sup> M1000 PRO multimode microplate reader by Tecan product image
Infinite® M1000 PRO multimode microplate reader



Average Rating: 4.4
30 Scientists have reviewed this product

5 out of 5
Ease of use
4 out of 5
After sales service
4 out of 5
Value for money


  • Status:

    Reviewer
  • Member since: 2017

  • Organization: PMV Pharma



  • Ease of use
    5 out of 5
    After sales service
    4 out of 5
    Value for money
    5 out of 5
Share this Review on LinkedinShare this Review on TwitterShare this Review on Facebook
Great results and quality.
Rating: 4.7

  • Application Area: Viability assays

"The product is very easy to use and the software is intuitive. We have had reproducible results in our cell viability assays."

Review date: 13 Apr 2017 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2017

  • Organization: Institut Pasteur



  • Ease of use
    4 out of 5
    After sales service
    4 out of 5
    Value for money
    3 out of 5
Share this ReviewShare this Review on TwitterShare this Review
a key element of the screening platform
Rating: 3.7

  • Application Area:High-throughput screening of chemical libraries

"Easy to use instrument, multimode plate reader integrated in a TECAN platform to screen chemical libraries and used to measure assays with readouts in absorbance, fluorescence and luminescence, checked once a year by TECAN (included in a maintenance contract). An improvement would be to have a much more accessible power switch, and also to increase the luminescence sensitivity."

Review date: 13 Apr 2017 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2017

  • Organization: Ideaya Biosciences



  • Ease of use
    5 out of 5
    After sales service
    4 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Setting up is easy
Rating: 4.7

  • Application Area:Compound screen

"Easy to use' great costumer support. Very intuitive set up"

Review date: 06 Feb 2017 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: University of Utah



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 5.0

  • Application Area:Biopharmaceutics

"Hands down this is the best combination plate reader I've ever used. "

Review date: 21 Oct 2015 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: Baylor College of Medicine



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 5.0

  • Application Area:Drug Discovery

"This is a user-friendly interface makes it very easy to teach our customers how to use the instrument and software."

Review date: 21 Oct 2015 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: Royal Military College of Canada



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 5.0

  • Application Area:Microbial Community Analysis

"It is easy to use. It has a greater software interface. No excessive plate heating. Specifically this product out-classes all other plate readers when it comes to continuous full-fluorescence scans on 96 well plates. "

Review date: 21 Oct 2015 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: AFMES



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 5.0
"A good reliable system that is easy to use. The software could be more user-friendly. But really I have no complaints."

Review date: 14 Oct 2015 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2012

  • Organization: Academia Sinica



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 5.0

  • Application Area:Phamacogenetics

"Easy to use, reasonable price and nice customer service."

Review date: 14 Oct 2015 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: Universidade de Santiago de Compostela



  • Ease of use
    5 out of 5
    After sales service
    4 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.3

  • Application Area:Drug Discovery

"This highly versatile reader is one of the stars of our lab. It's easy to use, and allows simple, reliable and reproducible detection of a variety of parameters used in the assay development and testing for early drug discovery."

Review date: 19 Sep 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Advanced Reviewer

  • Member since: 2014

  • Organization: Kalinga Institute of Medical Sciences



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 5.0

  • Application Area:Drug development

"Excellent product which simplifies the drug development process by a great extent. A must for those in the industry. "

Review date: 27 Aug 2014 | Infinite® M1000 PRO multimode microplate reader


  • Status:

    Reviewer

  • Member since: 2014

  • Organization: Texas A&M HSC



  • Ease of use
    4 out of 5
    After sales service
    4 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.0
"This instrument is easy to use as a standalone. Integrating this reader with a robotic plate handling system tends to slow down the initialization process. It does not initialize as the whole system started as we have to connect it with Magellan before initialize it with the robotic system. Magellan software is only available for this system to work, but we prefer icontrol."

Review date: 26 Aug 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: Weizmann Institute of Science



  • Ease of use
    4 out of 5
    After sales service
    4 out of 5
    Value for money
    2 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 3.3

  • Application Area:monitoring growth fluorescence of live cells

"Generally it's OK. One major issue is that OD is measured by four independent heads simultaneously. This provides speed, but if you need to compare OD measurements between the different heads, you will run into trouble as they have different offsets that are hard to control for. The shaking of plates is also not very efficient, but to my knowledge this is a problem for all readers."

Review date: 26 Aug 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2008

  • Organization: Michigan State University



  • Ease of use
    4 out of 5
    After sales service
    1 out of 5
    Value for money
    3 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 2.7

  • Application Area:Basic Research

" In less than 14 months from purchase, the Tecan M1000 Pro Microplate Reader has had two major repairs. On separate occasions, the luminescent and fluorescent modules broke (power-board and controller board - seems to be a batch of defective parts from a supplier) and had to fight with Tecan to get the repairs covered, as they wanted to charge me near $6K for each repair. I wish I had spent the money and purchased the equivalent Bio-Tek microplate reader, as reliability is a major concern now with the Tecan. Also, the Tecan microplate reader has constant connection issues with the computer as well. I cannot recommend this instrument for purchase. "

Review date: 26 Aug 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: University of Colorado - Childrens Hospital Colorado



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 5.0
"The Tecan M1000 Pro has many of the same features as its predecessors, making it easy to learn and use. The ability to transfer from an older Tecan microplate reader to this new version was simple and fast. I would recommend this instrument for anyone interested in using an easy format for ELISA testing."

Review date: 29 Jul 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: Fujifilm Diosynth Biotechnologies



  • Ease of use
    5 out of 5
    After sales service
    4 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.3

  • Application Area:Bilogics

"This is a very versatile instrument. It is easy to develop templates & powerful data analysis software. It is easy to integrate into automated systems. Plan to use it as a stand-alone unit. File format easy to export to other platforms/software. "

Review date: 22 Jul 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: University of Zurich



  • Ease of use
    4 out of 5
    After sales service
    4 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.0

  • Application Area:ELISA and HTRF Assays

"This is a reliable and robust plate-reader that can be used for a variety of assays."

Review date: 22 Jul 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2010

  • Organization: PROMEGA CORP



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.7

  • Application Area:Assay Development

"This is a highly versatility instrument, useful for all sorts of spectroscopy."

Review date: 22 Jul 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: Stanford University



  • Ease of use
    5 out of 5
    After sales service
    4 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.7

  • Application Area:Biochemistry

"It is really easy to use. It is very impressive GUI that makes it very easy to set up experiments."

Review date: 18 Jul 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: McMaster University



  • Ease of use
    5 out of 5
    After sales service
    4 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.7

  • Application Area:Immunoassays

"We just started to use this instrument to validate immunoassays that we are transferring from the bench to a TECAN Freedom EVO 200 workstation. The M1000 is perfectly integrated, it can work with EVO Standard and Plus but also as standalone feature. The M1000 is very versatile; we did not have to train for hours to get our first plates set up. Results layout and St. Curve plot are in a format that could be utilized straight for lab meeting presentations. We look forward to explore the many more options offered by this instrument. It has made our life really easy."

Review date: 18 Jul 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: Western University of Health Sciences



  • Ease of use
    4 out of 5
    After sales service
    4 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.3
"This is very good equipment. It is user friendly, easy to use and within budget."

Review date: 18 Jul 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: Vichem Chemie Ltd.



  • Ease of use
    4 out of 5
    After sales service
    5 out of 5
    Value for money
    3 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.0

  • Application Area:HTS Screening, Assay Development

"Tecan Infinite M1000 is an easy to use multimode reader with many options needed for non-radioactive assay development and screening. I especially like its fluorescent 3D scan option where one can easily check compounds' fluorescent properties."

Review date: 18 Jul 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: University of Pennsylvania



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.7

  • Application Area:Biochemistry / Biophysics

"Software is easy to use and more importantly, it is easy to teach others how do use it. Sensitivity and reproducibility can be an issue for some assays but I believe that is the case for most plate readers."

Review date: 18 Jul 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: University of Denver



  • Ease of use
    5 out of 5
    After sales service
    3 out of 5
    Value for money
    3 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 3.7

  • Application Area:HTS

"M1000 is a very versatile and easy to use instrument. However, there are more sensitive and speedier readers currently on the market. Also, there was a noticeable degradation of performance over the three year time frame; we have used it in a light manner."

Review date: 18 Jul 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: ETH Zurich



  • Ease of use
    4 out of 5
    After sales service
    5 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.3

  • Application Area:Luminescent Assay

"It is easy to use with all the tools you need for many applications."

Review date: 18 Jul 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: Friedrich-Schiller-University Jena



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 5.0

  • Application Area:Absorption and Fluorescence Assays

"We use it for analysis of absorption (XTT Assay) and fluorescence assays (lots different, depending on the fluorescence filter system). It works perfect and it can adept very easily with a new assay."

Review date: 18 Jul 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Advanced Reviewer

  • Member since: 2014

  • Organization: Research Institute of the Hospital de la Santa Creu i Sant Pau



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 5.0

  • Application Area:Core Lab Facility

"It's very easy-to-use , fulfils nearly all the needs of our institution regarding microplate reading (fluorescence, luminescence, colorimetric assays, etc...). It's absolutely recommendable. "

Review date: 18 Jul 2014 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2012

  • Organization: IIBR



  • Ease of use
    4 out of 5
    After sales service
    4 out of 5
    Value for money
    3 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 3.7

  • Application Area:ELISA

"Very good and reliable. Sensitive for immunoassay. Rapid for developing assays."

Review date: 27 Feb 2012 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2011

  • Organization: Molecular Analysis Lead



  • Ease of use
    4 out of 5
    After sales service
    4 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.0
"There were a few issues initially with the stacker, but once the servive rep adjusted them, the system is extremely reliable."

Review date: 23 Feb 2011 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2009

  • Organization: University of North Carolina



  • Ease of use
    3 out of 5
    After sales service
    4 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 3.7
"Software should be made more user friendly."

Review date: 02 Feb 2011 | Infinite® M1000 PRO multimode microplate reader
  • Status:

    Reviewer

  • Member since: 2010

  • Organization: Unc



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 5.0

Review date: 02 Feb 2011 | Infinite® M1000 PRO multimode microplate reader

The modular architecture of the Infinite M1000 PRO offers the flexibility to adapt to changing project objectives and assay requirements.

Premium Quad4 Monochromators™ technology ensures complete freedom of wavelength selection without the need for absorbance or fluorescence filters, providing maximum versatility and sensitivity for defining, fine-tuning and validating a wide range of assays and reagents. For stress-free, walkaway processing, Tecan’s Common Notification System (CNS) enables customers to remotely monitor their Infinite M1000 PRO through any networked computer or mobile device using Magellan™ software (v7.2) onwards. In combination with the Infinite’s optional Stacker module, this offers batch processing for up to 50 individual microplates, providing a convenient status update at the touch of a button for complete peace of mind.

The Infinite M1000 PRO offers multi-channel absorbance measurements, fluorescence intensity (FI) top and bottom reading, fast fluorescence polarization, and luminescence capability. It allows excitation, emission, absorbance and 3D scanning, and flexible wavelength selection – from UV to NIR – with patented adjustable bandwidth settings. For easy optimization of instrument set-up, it features automated z-focus adjustment in all top reading modes, as well as an Optimal Read function for enhanced assay performance and reliability. The Infinite M1000 PRO is ideal for applications such as biomolecular screening, enzymatic, G protein-coupled receptor (GPCR), molecular interaction and cell-based assays, DNA and RNA quantification, TRF and TR-FRET (HTRF®, LanthaScreen®), and AlphaScreen® and AlphaLISA® technology.

Product Overview

Infinite<sup>®</sup> M1000 PRO multimode microplate reader by Tecan product image

Infinite® M1000 PRO multimode microplate reader

Manufacturer Tecan

4.4 / 5.0 | 30 reviews