HiPrep 26/10 Desalting by Cytiva

Manufacturer Cytiva
4.7
/
5.0
  |  1 reviews
HiPrep 26/10 Desalting is a convenient, easy-to-use column prepacked 53 ml column with Sephadex G-25 Fine for desalting and buffer exchange. HiPrep 26/10 Desalting is packed with Sephadex G-25 Fine. The column has an internal diameter of 2.6 cm and a bed height of 10 cm. The gel bed volume is approximately 53 ml. The HiPrep column is made of biocompatible polypropylene with nylon frits. Both ends have M6 connections for direct connection to FPLC System. The set of connectors supplied makes it e... Read more
The supplier does not provide quotations for this product through SelectScience. Browse these related products instead


HiPrep 26/10 Desalting by Cytiva product image
HiPrep 26/10 Desalting



Average Rating: 4.7
1 Scientist has reviewed this product

5 out of 5
Ease of use
4 out of 5
After sales service
5 out of 5
Value for money


  • Status:

    Expert Reviewer
  • Member since: 2012

  • Organization: UNESP/IBILCE



  • Ease of use
    5 out of 5
    After sales service
    4 out of 5
    Value for money
    5 out of 5
Share this Review on LinkedinShare this Review on TwitterShare this Review on Facebook
Rating: 4.7

  • Application Area: Protein Purification

"HiPrep 26/10 Desalting pre-packed column are used to desalt/remove the excess salt which may have come from precipitation or ion exchange chromatography. It is also used to change the buffer. As compared to dialysis this method is rapid for removing salt and changing the buffer. There is no loss of proteins during this process. Although not commonly used but this column can separate a high molecular mass protein> 5000 from low molecular mass proteins."

Review date: 02 Jan 2014 | HiPrep 26/10 Desalting
HiPrep 26/10 Desalting is a convenient, easy-to-use column prepacked 53 ml column with Sephadex G-25 Fine for desalting and buffer exchange.

HiPrep 26/10 Desalting is packed with Sephadex G-25 Fine. The column has an internal diameter of 2.6 cm and a bed height of 10 cm. The gel bed volume is approximately 53 ml. The HiPrep column is made of biocompatible polypropylene with nylon frits. Both ends have M6 connections for direct connection to FPLC System. The set of connectors supplied makes it easy to connect the column to ÄKTAdesign and other high-performance systems.


HiPrep 26/10 Desalting Features:

  • Convenient, easy to use prepacked column with Sephadex™ G-25 Fine designed for desalting and buffer exchange
  • Replaces dialysis
  • Desalting of up to 15 ml sample in 1 min
  • Reliable and reproducible separations
  • Easy scaling-up by coupling columns in series
  • Well-suited to work where columns must be discarded after use
  • Compatible with ÄKTA™design systems and FPLC™ System

Product Overview

HiPrep 26/10 Desalting by Cytiva product image

HiPrep 26/10 Desalting

Manufacturer Cytiva

4.7 / 5.0 | 1 reviews