Genesis 40 E Benchtop Autoclave by Rodwell Scientific Instruments

Features40 litre CapacityCompact enough to fit onto a standard benchLarge enough to take 13 one-lire media bottles or 3 two-litre conical flasksOnly requires single-phase socket outlet.Technical Specification:DIMENSIONS Capacity: 40 litres Front loading Chamber Dimensions: 350 x 460 mm (diameter x length) Overall Dimensions : 520wide x 600deep x 720high (with control pod raised) Export Packed Dimensions (for shipping in mm): 680 x 750 x 750 Packed Weight: 110 kg 0.39 cubic metres SITE REQUIREMEN... Read more
The supplier does not provide quotations for this product through SelectScience. Browse these related products instead


Genesis 40 E Benchtop Autoclave by Rodwell Scientific Instruments product image
Genesis 40 E Benchtop Autoclave


0 Scientists have reviewed this product


Write the First Review

No Reviews

Features
40 litre Capacity
Compact enough to fit onto a standard bench
Large enough to take 13 one-lire media bottles or 3 two-litre conical flasks
Only requires single-phase socket outlet.

Technical Specification:
DIMENSIONS
  • Capacity: 40 litres Front loading
  • Chamber Dimensions: 350 x 460 mm (diameter x length)
  • Overall Dimensions : 520wide x 600deep x 720high (with control pod raised)
  • Export Packed Dimensions (for shipping in mm): 680 x 750 x 750 Packed Weight: 110 kg 0.39 cubic metres

    SITE REQUIREMENTS

    • 3 kW Electrically Heated
    • Electricity supply: 220/240 volt single phase socket outlet rated at 13 amps or optional 4 kW, 15 amp high speed rated @ 15 amps fixed supply or heavy duty socket.
    • Other Voltages available on request.
    • Drain Service: This autoclave can be supplied with a condense collector, so a drain service in not always necessary, however, a 22mm metal drain preferred. Drain service should be no higher than 100mm from floor level. If this is a problem please contact Rodwell because we may be able to raise the drain outlet on the autoclave.
    • Water Supply: Manual Fill. However, If automatic fill is specified a water supply will be required. This should be supplied from a 15mm cold water supply, supplied via a 10 gallon header tank and terminated at a stopcock within 2 metres run of the rear of the autoclave).
    SAFETY
    • Thermal lock to prevent the chamber from being opened if the chamber or load is above 80 deg.C.
    • Pressure lock to prevent the chamber from being opened if the chamber is above 0.04 bar.
    • If either lock fails the autoclave will fault in a safe conditions and lock fault will be indicated on the control panel and an alarm will sound.
    • Safety devices prevent the cycle being initiated until both door bolts and the outer door lock has been closed.
    • The vessel is designed in accordance with the general requirements of BS2646 Part 1 1993 and EN61010-2-41 1996.
    • All control circuits are 24 volts.

      CONSTRUCTION
      The chamber and door are constructed from stainless steel (BS1449 or 1501-321 S31 grade A where specified). The outer door is a G.R.P. moulding, which considerably reduces surface temperature. The doors are hinged at the side of the autoclave allowing for installation adjacent to other equipment. Sealing of chamber is effected by means of compressed silicone rubber "O" ring system. Closure is by means of a door bolt fitted with a heat resistant handle, which is interlocked with the steam release vent. The door bolt is fitted with a captive bolt device to safely reduce any residual pressure.
      Designed for mounting upon a bench or optional trolley for ease of movement.

      For more information please click here

Product Overview

Genesis 40 E Benchtop Autoclave by Rodwell Scientific Instruments product image

Genesis 40 E Benchtop Autoclave

Manufacturer Rodwell Scientific Instruments

Be the first to review this product