Dionex UltiMate 3000 XRS System

Dionex UltiMate 3000 XRS System
by Thermo Fisher Scientific
 3.6/5.0 (4 reviews)

The Dionex UltiMate 3000 XRS quaternary UHPLC systems provide lowest gradient delay volume in the market. Enjoy the shortest run times without compromising on flexibility and resolution. The UltiMate™ 3000 XRS quaternary UHPLC systems provide the lowest gradient delay volume in the market. Enjoy shortest run times without compromising on flexibility and resolution. Choose between the ultra-lo...read more

Request Pricing




Receive your quote directly from Thermo Fisher Scientific for Dionex UltiMate 3000 XRS System

Reviews

AVERAGE RATING: 3.6

4 scientists have reviewed this product

Write your own review



  • 3 out of 5EASE OF USE
  • 3 out of 5AFTER SALES SERVICE
  • 3 out of 5VALUE FOR MONEY

Jelle De Vos


Status:


See all reviews
Member since 2013

Organization:
Vrije Universiteit Brussel
Read more »
RATING: 3.7

  • 3 out of 5EASE OF USE
  • 4 out of 5AFTER SALES SERVICE
  • 4 out of 5VALUE FOR MONEY




Review date: 08 Aug 2013

Application Area: Protein separations on monolith columns
Dionex UltiMate 3000 XRS System

"Very precise system with excellent user-friendly software. Great design for viper coupling and thus low extra-column band broadening. Bad design of the pump lay-out."

Read 4 reviews

Ya Ou


Status:


See all reviews
Member since 2013

Organization:
University of Pittsburgh
Read more »
RATING: 3.0

  • 3 out of 5EASE OF USE
  • 3 out of 5AFTER SALES SERVICE
  • 3 out of 5VALUE FOR MONEY




Review date: 01 Jul 2013

Application Area: peptides
Dionex UltiMate 3000 XRS System

"This system is very finicky and required constant maintenance and troubleshooting after the first three months of use. The loading pump has occasional problems holding pressure and sometimes has problems building up pressure. The Viper fittings and columns, however, are extremely robust. The zero void volume is wonderful. Troubleshooting personnel’s are helpful but an annual renewal is required at high cost."

Douglas Nolan


Status:


See all reviews
Member since 2010

Organization:
Trinity University
Read more »
RATING: 4.3

  • 4 out of 5EASE OF USE
  • 5 out of 5AFTER SALES SERVICE
  • 4 out of 5VALUE FOR MONEY




Review date: 28 May 2013

Application Area: Stationary Phase Study
Dionex UltiMate 3000 XRS System

"Interface is difficult to navigate--confusing how to overlay data, etc. Difficult to access previous data and compare it in various ways."

Neil Spingarn


Status:


See all reviews
Member since 2010

Organization:
S&N Labs
Read more »
RATING: 3.3

  • 4 out of 5EASE OF USE
  • 3 out of 5AFTER SALES SERVICE
  • 3 out of 5VALUE FOR MONEY




Review date: 18 Mar 2013

Application Area: general
Dionex UltiMate 3000 XRS System

"This is a large, relatively complex system but has worked well over the past year. Maintenance isn't the easiest but it hasn't required more than the expected seals and a lamp replacement."

Description

 

The Dionex UltiMate 3000 XRS quaternary UHPLC systems provide lowest gradient delay volume in the market. Enjoy the shortest run times without compromising on flexibility and resolution.

The UltiMate™ 3000 XRS quaternary UHPLC systems provide the lowest gradient delay volume in the market. Enjoy shortest run times without compromising on flexibility and resolution. Choose between the ultra-low dispersion UltiMate 3000 XRS Autosampler with its 3 well plate capacity or the UltiMate 3000 XRS Open Autosampler to extend the capacity up to 12 well plates. Combine this power with our industry-leading choice of UHPLC-compatible detection technologies.

Choose between the ultra-low dispersion UltiMate 3000 XRS Autosampler with its 3 well plate capacity or the UltiMate 3000 XRS Open Autosampler to extend the capacity up to 12 well plates. Combine this power with our industry-leading choice of UHPLC-compatible detection technologies.


Dionex UltiMate 3000 XRS System Features:

  • Quaternary UHPLC system with extended pressure range up to 1250 bar, enabling the use of very long, sub-2 μm particle columns
  • Lowest delay volume for ultrafast, ballistic gradients with up to four solvents
  • The solution for high sample throughput and ultra-high resolution chromatography
  • Ultralow dispersion UV detection for additional sample information
  • Seamless LC/MS integration

Product Overview

Dionex UltiMate 3000 XRS System by Thermo Fisher Scientific
Dionex UltiMate 3000 XRS System




  • 3out of 5EASE OF USE
  • 3 out of 5AFTER SALES SERVICE
  • 3 out of 5VALUE FOR MONEY





Request Pricing

SelectScience Trusted Banner