Status:
ReviewerMember since: 2020
Organization: CNRS
Great instrument! I recommend it!
Application Area: qualification and quantitation of DNA
"The Fragment Analyzer is far superior to its competitors in terms of ease of use and quality of results. The longer capillaries allow for greater resolution than the LabChip or the BioAnalyzer. The ProSize software is intuitive but could stand a few upgrades in terms of allowing specific group color-coding , very easy to use and comfortable for all"
Status:
ReviewerMember since: 2019
Organization: Université De Mons
Obtained results impossible without this instrument
Application Area:ligands interaction study
"Very efficient device, unique in its field. Offer adapatable conditions of coating andrinsing."
Status:
ReviewerMember since: 2021
Organization: Georgia Institute of Technology
It is a great instrument in our lab. We use it very frequently.
Application Area:Analyze anion in paper industry
"It is very user friendly and easy to maintain. The equipment is very good quality and it does not need much after sale care. The price is reasonable too."
Status:
ReviewerMember since: 2020
Organization: Amneal Pharmaceuticals
Reliable and consistent results. Low maintenance and break down.
Application Area:Separation technology at very low concentrations
"It is a wonderful instrument that can be integrated with both Agilent open lab and Empower 3. It is used for separation analyses at very low concentration with great resolution. Results are accurate and reproducible. Service from Agilent is outstanding."
Status:
ReviewerMember since: 2017
Organization: University of Debrecen
Very useful instrument with low measurement costs
Application Area:Analysis of digested proteins
"The use of the instrument is very simple, most maintenance works can be done by yourself with ease in a couple of minutes. The UV detector of it is really excellent, it is even better than the older HP 3D CE instruments. The instrument gives reproducible results, and it works quite well. The only drawback can be related to the software, only very rarely but sometimes it lags or freezes, but it is possible that it is only a one-time problem in our case. Anyways, a great instrument if you're looking for a CE instrument in your lab. The maintenance and measurements are very cheap, which is also an advantage."
Status:
ReviewerMember since: 2011
Organization: Bucknell University
Application Area:Capillary Electrophoresis Separations
"If maintained well by the user, this instrument is reliable and effective for a variety of applications including CZE, MEKC, EMMA, and any other typical CE method."
Status:
ReviewerMember since: 2011
Organization: University of Colorado at Colorado Springs
"A sturdy, fairly reliable instrument but service is expensive for simple fixes."
Status:
ReviewerMember since: 2010
Organization: LSU Chemistry
Application Area:Separation of nucleotides
"Easy to use and reliable, but to collect data and transfer it is not that easy."
Status:
ReviewerMember since: 2011
Organization: Wake Forest University
"the ce system is user friendly. the software makes it easy to set up and run a method. the data analysis software is also very useful."
The Agilent 7100 CE System can be used as a standalone unit, as the separations component of a CE/MS, or as a complementary, orthogonal technology to LC. Extended light path capillaries increase the system’s sensitivity, while the replenishment system enables high-throughput operation.
The system offers fast separations with exceptional efficiency and resolution for analytical challenges that can often only be met with difficulty by LC. In addition, several separation modes can be run on a single instrument. This makes CE a very versatile technique for a broad range of applications and separation challenges.
Features:
Manufacturer Agilent Technologies
4.0 / 5.0 | 23 reviews