BRAND PLT™ Pipette Leak Testing Unit by BRANDTECH® Scientific, Inc.

Manufacturer BRANDTECH® Scientific, Inc.  |  Available Worldwide
5.0
/
5.0
  |  1 reviews
The BRAND PLT™ Pipette Leak Tester provides a quick daily functional check of air displacement pipettes. By ruling out leakage, the cause of most pipetting inaccuracy, it provides an extra level of assurance between instrument calibrations. An entirely new class of device, the PLT™ quantifies leakage from the entire pipette system and provides a simple PASS/FAIL result for all common brands and sizes of pipettes. PASS/FAIL criteria are based on data generated over 35 years, failing instruments w... Read more


BRAND PLT™ Pipette Leak Testing Unit by BRANDTECH® Scientific, Inc. product image
BRAND PLT™ Pipette Leak Testing Unit
Buy Now

Place your order directly with the manufacturer.




Average Rating: 5.0
1 Scientist has reviewed this product

5 out of 5
Ease of use
5 out of 5
After sales service
5 out of 5
Value for money


  • Status:

    Reviewer
  • Member since: 2015

  • Organization: Oxford University



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this Review on LinkedinShare this Review on TwitterShare this Review on Facebook
Rating: 5.0

  • Application Area: To check the integrity of o-rings on pipettes

"This helps sorting out pipettes which needs a simple change of o-ring from the pipettes which needs additional servicing, saving the department time and money."

Review date: 27 Apr 2015 | BRAND PLT™ Pipette Leak Testing Unit
The BRAND PLT™ Pipette Leak Tester provides a quick daily functional check of air displacement pipettes. By ruling out leakage, the cause of most pipetting inaccuracy, it provides an extra level of assurance between instrument calibrations.

An entirely new class of device, the PLT™ quantifies leakage from the entire pipette system and provides a simple PASS/FAIL result for all common brands and sizes of pipettes. PASS/FAIL criteria are based on data generated over 35 years, failing instruments will exhibit gravimetrically detectable errors. Instruments can be tested with or without tips, statically or dynamically, providing diagnostic assistance in case of pipette failure. Testing takes only seconds, intuitive menu-driven software combined with a jog-wheel and affirmative/negative buttons, makes it easy to select the correct test parameters. An optional four channel adapter allows for rapid testing of multichannel pipettes. Integrated self-diagnostics ensure reliable results.