BlueScreen HC: The luminescent adaptation of GreenScreen

BlueScreen HC: The luminescent adaptation of GreenScreen
Click to Playtemp-thumb
by Gentronix Ltd.


BlueScreen HC is based on the fast, accurate GreenScreen HC genotoxicity assay from Gentronix Ltd. BlueScreen HC uses the same human-derived, p53-competent TK6 cells to host a patented reporter system that exploits the proper regulation of the GADD45a gene. However, in place of GFP, BlueScreen HC utilizes a luciferase from the marine copepod Gaussia princeps to generate a luminescent output....read more

Request Pricing




Receive your quote directly from Gentronix Ltd. for BlueScreen HC: The luminescent adaptation of GreenScreen

Description

 

BlueScreen HC is based on the fast, accurate GreenScreen HC genotoxicity assay from Gentronix Ltd.

BlueScreen HC uses the same human-derived, p53-competent TK6 cells to host a patented reporter system that exploits the proper regulation of the GADD45a gene. However, in place of GFP, BlueScreen HC utilizes a luciferase from the marine copepod Gaussia princeps to generate a luminescent output.

The BlueScreen luminescent assay delivers both high specificity and high sensitivity and detects all common mechanistic classes of genotoxin, just like GreenScreen HC. The 96-well microplate format of BlueScreen is rapid to set up and results are generated after 48 hours’ incubation. A single microplate is sufficient for the simultaneous testing of 8 compounds and the protocol is readily automated using standard laboratory equipment. The superior signal-to-noise ratio makes it more suitable for adaptation to even higher throughput screening in 384-well format. The BlueScreen luminescent output also circumnavigates issues of test compound autofluorescence.

Key Principles of BlueScreen:

GADD45a plays an important role in mediating the adaptive response to genotoxic stress. The patented system incorporates complex regulatory elements to enable a faithful GADD45a response. The assay generates positive results for direct-acting mutagens, clastogens, as well as aneugens, and topoisomerase and polymerase inhibitors. Importantly, correct negative results are produced for non-carcinogens, many of which give misleading positive results in other in vitro genotoxicity tests. A metabolic activation protocol using rodent S9 liver extract extends the range of compounds detected to include genotoxic metabolites.

Bluescreen Assay Protocol:
BlueScreen HC uses a single cell strain, which permits 8 compounds to be tested across 8 dilutions (2-fold serial), together with untreated and positive controls, in one 96-well microplate. After arraying test compounds and dilutions, growing cells are added to each well. For studies without S9 metabolic activation data are collected after incubation (48h) using a multimode microplate reader. For studies incorporating S9 metabolic activation, cells are washed after a 3h incubation with test compound and S9. Measurements are made by microplate reader after a further 45h incubation period. Simple software gives automated decisions and a clear graphical output, including a complimentary indication of cytotoxicity (RCD).

Product Overview

BlueScreen HC: The luminescent adaptation of GreenScreen by Gentronix Ltd.