Description
Extractions that normally take hours can be done in minutes using Thermo Scientific Accelerated Solvent Extraction System (ASE®). Compared to techniques like Soxhlet and sonication, ASE generates results in a fraction of the time. In addition to speed, ASE offers a lower cost per sample than other techniques by reducing solvent consumption by up to 90%.
• Extractions in minutes
• Dramatic solvent reduction
• Wide range of applications
• Approved for use by the U.S. EPA and CLP Program
• Automated Extraction of up to 24 samples
• Sample Cell sizes: 1, 5, 11, 22, and 33 mL
• Collection bottle 40 or 60 mL
• Operating pressure 500–3000 PSI (35–200 Bar)
Time is of the essence in most analytical laboratories. By using conventional liquid solvents at elevated temperatures and pressures, ASE increases the efficiency of the extraction process. Increased temperature accelerates the extraction kinetics, and elevated pressure keeps the solvent below its boiling point, thus enabling safe and rapid extractions. When an extraction takes only 15 min to complete, you can get to the data faster than ever before.
Although ASE uses the same aqueous and organic solvents as traditional extraction methods, it uses them more efficiently. Therefore, you use less solvent volume per sample, and instant savings for your operation. A typical ASE extraction is done using only 15-45 mLs of solvent.
Application notes and news
Reviews
Charlotta Turner![]() Status: See all reviews Member since 2011 Organization: Lund University Read more » | RATING: 5.0 ![]()
"very good hot solvent extraction system!" |
Vara Prasad Sakampally![]() Status: See all reviews Member since 2011 Organization: South Dakota State University Read more » | RATING: 4.6 ![]()
"It works well." |
Vinod Kumar Bathula![]() Status: See all reviews Member since 2011 Organization: South Dakota State University Read more » | RATING: 5.0 ![]()
"This is good and easy to use." |
Catherine Sloan![]() Status: See all reviews Member since 2011 Organization: NOAA Read more » | RATING: 4.0 ![]()
"one system in use for a long time with a few problems. another system in use for a few years with severel problems." |
Dr Aarif H El-Mubarak![]() Status: See all reviews Member since 2006 Organization: The Supreme Council for Environment & Natural Reserves, Qatar Read more » | RATING: 5.0 ![]()
"This system is perfect." |
Edmond Lee![]() Status: See all reviews Member since 2005 Organization: Tegent Technology Read more » | RATING: 3.6 ![]()
|
Arokiasamy![]() Status: See all reviews Member since 2003 Organization: - Read more » | RATING: 3.3 ![]()
"" |
Feedback
Request info
Write a review
Sharing your experience will help scientists like you. Achieve Reviewer Status and Win an iPad 3 (All reviews published will be entered into the next drawing on May 31st 2013).


(what's this)