Ambassador 158 Vacuum Front Loading Autoclave by Rodwell Scientific Instruments

The most efficient vacuum autoclave available utilising leak free ‘Pneu-valve’ technology. Direct Steam Heated, 158 litre capacity.Electric Steam Generator available as an option if no steam is availableDIMENSIONS Capacity: 158 litres front loading Chamber Dimensions(mm): 460 x 960 (diameter x depth) Overall Dimensions (mm): 650 wide x 1310 deep x 1240 high Steam Generator Dimensions (if no mains steam is available): 620 wide x 1000 deep x 700 high Steam Generator can be built in underneath the ... Read more


Ambassador 158 Vacuum Front Loading Autoclave by Rodwell Scientific Instruments product image
Ambassador 158 Vacuum Front Loading Autoclave


0 Scientists have reviewed this product


Write the First Review

No Reviews

The most efficient vacuum autoclave available utilising leak free ‘Pneu-valve’ technology. Direct Steam Heated, 158 litre capacity.
Electric Steam Generator available as an option if no steam is available

DIMENSIONS

  • Capacity: 158 litres front loading Chamber Dimensions(mm): 460 x 960 (diameter x depth)
  • Overall Dimensions (mm): 650 wide x 1310 deep x 1240 high
  • Steam Generator Dimensions (if no mains steam is available): 620 wide x 1000 deep x 700 high
  • Steam Generator can be built in underneath the autoclave, if required.
  • This will increase the overall height of the autoclave by 400mm
  • Export Packing Specifications (for shipping in mm): 1480 wide x 740 deep x 2000 high
  • 2.19 cu metre. Weight: 500 Kg

    CYCLE PARAMETERS

    • SteriliseTimer: 0 to 119 minutes
    • Temperature control from chamber: 100 to 137 deg.C.
    • Maximum design pressure: 2.62 Bar (38 psig)
    • Vacuum depth: -0.8bar (-0.9 bar optional)
    • No of pre-vacuum pulses:Variable up to a maximum of 6.
    • 7 different types of pre-vacuum cycle are available. Each vacuum cycle has different depths and pulses.
    • Post vacuum drying time: 0 to 120 minutes (on/off), with heat pulses.
    • Non vacuum cycles: Any number of non-vacuum cycles can be pre-programmed up to a maximum of 24.
    VACUUM PARAMETERS

    • 5 different types of vacuum cycle is available. Each vacuum cycle has different depths and pulses.
    • Up to 6 pre-vacuum and steam pulses before heat cycle begins.
    • Each vacuum pulse up to -0.8bar for maximum air removal of even the most difficult porous loads.
    • Post vacuum and heat pulse drying cycle.
    • Up to 119 minutes drying time

      VACUUM SUMMERY

      A vacuum autoclave operating in basic form is much like a direct steam autoclave. However, in the case of a vacuum autoclave, a liquid ring vacuum pump and associated control valves are added. These valves have to be different from those used in non vacuum autoclaves as they have to be leak free and bi-directional- in other words, be able to operate just as efficiently with vacuum and pressure either side.

      It is for this reason that Rodwell Scientific Instruments utilise ‘Pneu-valve technology’. The Rodwell ‘Pneu-valve’ system is designed to seal 100%- totally leak-free. The Pneuvalve system will function just as well will pressure or vacuum on either side. The majority of vacuum autoclave systems can not do this. This is why the Rodwell Pneu-valve system can draw almost absolute vacuum (typically –0.8 to -0.9bar), whereas many manufactures can only manage –0.4 bar. This ensures that there will be no cold spots, in even the most porous of loads and 100% sterilisation is achieved.

      There is another advantage of the Pneu-valve system- reliability. Many other valves can be affected by debris such as broken glass of lime scale. Pneu-valve will not. If debris does get caught within it, the valve still closes and crushes any debris out of the way as it does so.

      Finally, a steam supply is required. Ideally, this needs to be supplied to the autoclave at around 3.5 bar for the best steam penetration and drying properties. Obviously, a steam supply is not always available and if there is one, it is often unreliable. Therefore, to meet this demand Rodwell manufacture a range of heavy duty steam generating systems and accessories capable of generating steam to the correct volume and pressure, up to a maximum of 4 bar.

      There are many cheaper vacuum systems available; all designed with cost rather then performance in mind. However, the additional investment in a Rodwell vacuum system will save money and the aggravation associated with traditional vacuum autoclave systems. Financially speaking, a pay back period will be realised very quickly.

      • Greater reliability means reduced downtime and lower maintenance costs.
      • Not susceptible to load breakage’s or hard water problems.
      • Leak free operation ensures full vacuum is drawn every time and full sterilisation is achieved.
      • Modular ‘Pnue-valve’ design means repairs can be effected easily and cost effectively.



        visit www.rodwell-autoclave.com for further information

Product Overview

Ambassador 158 Vacuum Front Loading Autoclave by Rodwell Scientific Instruments product image

Ambassador 158 Vacuum Front Loading Autoclave

Manufacturer Rodwell Scientific Instruments

Be the first to review this product