HP-FFAP Columns by Agilent Technologies

5.0
/
5.0
  |  1 reviews
Agilent J&W HP-FFAP is designed primarily for the analysis of organic acids, free fatty acids, or samples that require quantitation of acidic impurities. The FFAP stationary phase is modified with acid to provide a very inert column that can accommodate the demanding analysis of acids dissolved in water. 


HP-FFAP Columns by Agilent Technologies product image
HP-FFAP Columns
Request Pricing

Receive your quote directly from the manufacturer.




Average Rating: 5.0
1 Scientist has reviewed this product

5 out of 5
Ease of use
5 out of 5
After sales service
5 out of 5
Value for money


  • Status:

    Reviewer
  • Member since: 2021

  • Organization: sirim berhad



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this Review on LinkedinShare this Review on TwitterShare this Review on Facebook
Good result
Rating: 5.0

  • Application Area: Alcoholic beverages

"Good quality and good reproducability"

Review date: 15 Nov 2021 | HP-FFAP Columns

Agilent J&W HP-FFAP is designed primarily for the analysis of organic acids, free fatty acids, or samples that require quantitation of acidic impurities. The FFAP stationary phase is modified with acid to provide a very inert column that can accommodate the demanding analysis of acids dissolved in water. Free fatty acids up to C24 can be analyzed by HP-FFAP without costly and time-consuming derivatization. HP-FFAP does not require priming (several injections of acids) and so accurate results can be obtained quickly.

Features:

  • Nitroterephthalic acid modified polyethylene glycol
  • High polarity
  • Designed for the analysis of volatile fatty acids and phenols
  • Replaces OV-351
  • Bonded and cross-linked; solvent rinsable
  • Close equivalent to USP Phase G35
  • Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
  • For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column

Note: We do not recommend the use of water or methanol to rinse HP-FFAP GC columns

Similar Phases: Stabilwax-DA, Nukol, 007-FFAP, BP21, AT-1000, OV-351

Product Overview

HP-FFAP Columns by Agilent Technologies product image

HP-FFAP Columns

Manufacturer Agilent Technologies

5.0 / 5.0 | 1 reviews