CP-Sil 88 Columns for Dioxins by Agilent Technologies

5.0
/
5.0
  |  1 reviews
Agilent J&W CP-Sil 88 for Dioxins has a very high polarity and a specific selectivity for dioxin and dibenzofuran separations. The column is supplied with an integrated retention gap to avoid problems with solvent condensation, thus allowing repeated splitless injections without phase deterioration, extending column life. 


CP-Sil 88 Columns for Dioxins by Agilent Technologies product image
CP-Sil 88 Columns for Dioxins
Request Pricing

Receive your quote directly from the manufacturer.




Average Rating: 5.0
1 Scientist has reviewed this product

5 out of 5
Ease of use
5 out of 5
After sales service
5 out of 5
Value for money


  • Status:

    Advanced Reviewer
  • Member since: 2019

  • Organization: Kansas State University



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this Review on LinkedinShare this Review on TwitterShare this Review on Facebook
Great results
Rating: 5.0

  • Application Area: Fatty Acid

"I've been using CP-Sil 88 for fatty acid for long time and give me good results, high resolution, almost no problem, even changing the column few times. I've been able to separate and identify more than 42 FAME in once."

Review date: 02 Jun 2023 | CP-Sil 88 Columns for Dioxins

Agilent J&W CP-Sil 88 for Dioxins has a very high polarity and a specific selectivity for dioxin and dibenzofuran separations. The column is supplied with an integrated retention gap to avoid problems with solvent condensation, thus allowing repeated splitless injections without phase deterioration, extending column life. In addition, because of the integrated retention gap, data quality is considerably improved. For the shortest analysis times, a series of thin-film coated columns is available that allow applications up to 270 °C in temperature-programmed mode.

Features:

  • High polarity stationary phase with specific selectivity for dioxins and dibenzofuran separations
  • Integrated retention gap eliminates leaks and extends column lifetime with splitless injections
  • 2,3,7,8-TCDD can be determined at low concentrations
  • For fast runtimes, thin film configurations are available with maximum temperature program limit of 270 °C
  • Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
  • For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column

Similar Phases: SP-2560, SP-2330, BPX-70, BPX-90

Product Overview

CP-Sil 88 Columns for Dioxins by Agilent Technologies product image

CP-Sil 88 Columns for Dioxins

Manufacturer Agilent Technologies

5.0 / 5.0 | 1 reviews