Run trace-level pesticide residue analysis 3x faster with a single-injection approach. The Agilent 5975 Series GC/MS system utilizing the capillary flow three-way splitter, trace ion detection, and Agilent Deconvolution Reporting Software (DRS) for the MSD ChemStation, eliminates multiple injections and analysis from a sample extract. This process is capable of identifying compounds below 10 p...read more

Request Pricing




Receive your quote directly from Agilent Technologies for Agilent 5975 Series GC/MS system

Reviews

AVERAGE RATING: 4.0

1 scientist has reviewed this product

Write your own review



  • 4 out of 5EASE OF USE
  • 4 out of 5AFTER SALES SERVICE
  • 4 out of 5VALUE FOR MONEY

bryan choong


Status:


See all reviews
Member since 2010

Organization:
PGEO Edible Oils Sdn Bhd
Read more »
RATING: 4.0

  • 4 out of 5EASE OF USE
  • 4 out of 5AFTER SALES SERVICE
  • 4 out of 5VALUE FOR MONEY




Review date: 26 Nov 2010

Agilent 5975 Series GC/MS system

Description

 

Run trace-level pesticide residue analysis 3x faster with a single-injection approach.

The Agilent 5975 Series GC/MS system utilizing the capillary flow three-way splitter, trace ion detection, and Agilent Deconvolution Reporting Software (DRS) for the MSD ChemStation, eliminates multiple injections and analysis from a sample extract. This process is capable of identifying compounds below 10 pg on column in full-scan mode, thus removing the demand for chromatographic resolution. In one, 15-minute full-scan GC/MS analysis, all the target analytes can be found in one-tenth of the current FDA/CFSAN total analysis time.

GC/MS methods are widely used for pesticides analysis especially for the screening of large numbers of target compounds in complex matrices. Full-scan EI methods offer many advantages for broad-range screening, such as an unlimited number of targets, full-spectrum identity confirmation, and library searching for identification of non-targets. Technologies such as Capillary Flow Technology backflushing, Deconvolution Reporting Software (DRS), and a Pesticides and Endocrine Disruptors database can increase the number of targets screened while reducing the time required per sample. Agilent GC/MS analyzers are ready to use and simplify startup. The analysis method makes use of the latest GC/MS technologies, improving productivity in the laboratory and producing consistent, high-quality data from day one.