Thermo Scientific™ Acclaim Carbamate LC Column by Thermo Fisher Scientific

Manufacturer Thermo Fisher Scientific  |   Model: IQLAALGABXFAITMBBM
5.0
/
5.0
  |  1 reviews
The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity. Acclai... Read more


Thermo Scientific™ Acclaim Carbamate LC Column by Thermo Fisher Scientific product image
Thermo Scientific™ Acclaim Carbamate LC Column
Request Pricing

Receive your quote directly from the manufacturer.




Average Rating: 5.0
1 Scientist has reviewed this product

5 out of 5
Ease of use
5 out of 5
After sales service
5 out of 5
Value for money


  • Status:

    Advanced Reviewer
  • Member since: 2018

  • Organization: KOTITI VIETNAM LIMITED



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this Review on LinkedinShare this Review on TwitterShare this Review on Facebook
Great result.
Rating: 5.0

  • Application Area: Environmental analysis

"High throughput result, good resolution and peak shape"

Review date: 27 Oct 2018 | Thermo Scientific™ Acclaim Carbamate LC Column

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2.

Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

Acclaim Carbamate LC Column Features:

 

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) mobile phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Column Details:

  • Chemistry: Proprietary alkyl group
  • Length: 100, 150, 250 mm
  • ID: 2.1, 3.0, 4.6 mm