Acclaim® 120 C18 Reversed-Phase LC Column

High Performance Reversed-Phase Columns for the Separation of Small Molecules. The Acclaim® 120 columns are designed for high resolution reversed-phase separations. The very high surface coverage and very low metal content together result in columns with excellent efficiencies. These columns provide exceptional performance for a variety of applications in the pharmaceutical, chemical, environmental, and food separations areas.Acclaim 120 C18 columns have high surface coverage, resulting in high-capacity columns. They are stable between pH 2 and 8 and available in 3 and 5 μm particles sizes, and 4.6, 3.0, and 2.1 mm-diameters, with an average pore diameter of 120 Å. Acclaim 120 C18 is also available in 2.2µm RSLC format (see Acclaim Rapid Separation LC columns section for more details). A...Read more

Receive your quote directly from Thermo Fisher Scientific for Acclaim® 120 C18 Reversed-Phase LC Column

=

Reviews

1 Scientist has reviewed this product


Write your own review

Average Rating: 4.0

Ease of use
5 out of 5
After sales service
5 out of 5
Value for money
2 out of 5

Description

High Performance Reversed-Phase Columns for the Separation of Small Molecules.

The Acclaim® 120 columns are designed for high resolution reversed-phase separations. The very high surface coverage and very low metal content together result in columns with excellent efficiencies. These columns provide exceptional performance for a variety of applications in the pharmaceutical, chemical, environmental, and food separations areas.

Acclaim 120 C18 columns have high surface coverage, resulting in high-capacity columns. They are stable between pH 2 and 8 and available in 3 and 5 μm particles sizes, and 4.6, 3.0, and 2.1 mm-diameters, with an average pore diameter of 120 Å. Acclaim 120 C18 is also available in 2.2µm RSLC format (see Acclaim Rapid Separation LC columns section for more details). All phases are LC/MS compatible because of the low silica bleed that results from the stable bonding procedure.


Acclaim® 120 C18 Reversed-Phase LC Column Features:

  • Ultrapure silica with high-density bonding for low silanol activity
  • Very high efficiencies for maximum resolution
  • Reproducible manufacturing practices for reproducible column-to-column performance
  • LC/MS compatible

Column Details:

  • Particle Size: 3, 5 µm
  • Pore Size: 120 Å
  • Length: 50, 100, 150, 250 mm
  • ID: 2.1, 3.0, 4.6 mm