Acclaim® 120 C18 Reversed-Phase LC Column

Acclaim® 120 C18 Reversed-Phase LC Column
by Thermo Fisher Scientific
 4.0/5.0 (1 review)

High Performance Reversed-Phase Columns for the Separation of Small Molecules. The Acclaim® 120 columns are designed for high resolution reversed-phase separations. The very high surface coverage and very low metal content together result in columns with excellent efficiencies. These columns provide exceptional performance for a variety of applications in the pharmaceutical, chemical, environ...read more

Request Pricing




Receive your quote directly from Thermo Fisher Scientific for Acclaim® 120 C18 Reversed-Phase LC Column

Reviews

AVERAGE RATING: 4.0

1 scientist has reviewed this product

Write your own review



  • 5 out of 5EASE OF USE
  • 5 out of 5AFTER SALES SERVICE
  • 2 out of 5VALUE FOR MONEY

Arcady Braun


Status:


See all reviews
Member since 2011

Organization:
Moscow State University
Read more »
RATING: 4.0

  • 5 out of 5EASE OF USE
  • 5 out of 5AFTER SALES SERVICE
  • 2 out of 5VALUE FOR MONEY




Review date: 20 Sep 2011

Acclaim® 120 C18 Reversed-Phase LC Column

"One of the best columns available."

Description

 

High Performance Reversed-Phase Columns for the Separation of Small Molecules.

The Acclaim® 120 columns are designed for high resolution reversed-phase separations. The very high surface coverage and very low metal content together result in columns with excellent efficiencies. These columns provide exceptional performance for a variety of applications in the pharmaceutical, chemical, environmental, and food separations areas.

Acclaim 120 C18 columns have high surface coverage, resulting in high-capacity columns. They are stable between pH 2 and 8 and available in 3 and 5 μm particles sizes, and 4.6, 3.0, and 2.1 mm-diameters, with an average pore diameter of 120 Å. Acclaim 120 C18 is also available in 2.2µm RSLC format (see Acclaim Rapid Separation LC columns section for more details). All phases are LC/MS compatible because of the low silica bleed that results from the stable bonding procedure.


Acclaim® 120 C18 Reversed-Phase LC Column Features:

  • Ultrapure silica with high-density bonding for low silanol activity
  • Very high efficiencies for maximum resolution
  • Reproducible manufacturing practices for reproducible column-to-column performance
  • LC/MS compatible

Column Details:

  • Particle Size: 3, 5 µm
  • Pore Size: 120 Å
  • Length: 50, 100, 150, 250 mm
  • ID: 2.1, 3.0, 4.6 mm

Product Overview

Acclaim® 120 C18 Reversed-Phase LC Column by Thermo Fisher Scientific
Acclaim® 120 C18 Reversed-Phase LC Column




  • 5out of 5EASE OF USE
  • 5 out of 5AFTER SALES SERVICE
  • 2 out of 5VALUE FOR MONEY





Request Pricing

SelectScience Trusted Banner
Why make an inquiry with SelectScience?