SCIEX TOF/TOF™ 5800 System by SCIEX

Manufacturer SCIEX
4.6
/
5.0
  |  4 reviews
The SCIEX TOF/TOFTM 5800 System provides the fastest and most confident path to the identification and relative quantitation of proteins. The systems unmatched speed and sensitivity make it the ideal platform for biomarker discovery, MALDI mass spectrometry imaging, and protein identification. Features of the TOF/TOFTM 5800 System: More than 10X faster data acquisition with new 1KHz laser and DynamicExitTM algorithm Unique OPtiBeamTM on-axis laser irradiation increases sensitivity in ... Read more


SCIEX TOF/TOF™ 5800 System by SCIEX product image
SCIEX TOF/TOF™ 5800 System



Average Rating: 4.6
4 Scientists have reviewed this product

5 out of 5
Ease of use
5 out of 5
After sales service
4 out of 5
Value for money


  • Status:

    Expert Reviewer
  • Member since: 2016

  • Organization: Novartis Pharma AG



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    4 out of 5
Share this Review on LinkedinShare this Review on TwitterShare this Review on Facebook
Robust instrument for proteomics applications
Rating: 4.7

  • Application Area: Reliable MALDI-TOF/TOF for proteomics applications

"The TOF/TOF 5800 System was used to identify peptides not approachable by ESI-based instruments. Interestingly, the instrument allowed to identify a totally different set of phosphopeptides. Furthermore, the MS was used for quality control of proteins following site-specific tagging as well as for the identification of peptides from large-scale proteomics experiments. Easy to use and very robust."

Review date: 03 Nov 2017 | SCIEX TOF/TOF™ 5800 System
  • Status:

    Expert Reviewer

  • Member since: 2016

  • Organization: Novartis Pharma AG



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Esay to use and reliable, complementing the peptide information obtained by ESI
Rating: 4.7

  • Application Area:Proteomics from a different angle

"MALDI-TOF/TOF was applied to complete the identification of phosphopeptides. A comprehensive overview was achieved by compining ESI and MALDI. This system was of great help for the task."

Review date: 28 Jul 2017 | SCIEX TOF/TOF™ 5800 System
  • Status:

    Expert Reviewer

  • Member since: 2016

  • Organization: Novartis Pharma AG



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Different peptides identified to electrospray ionization
Rating: 4.7

  • Application Area:Orthogonal approach for proteomics

"The TOF/TOF 5800 System was used for LC-MS approaches (offline separation of complex tryptic peptide mixtures, spotting on target plates and analysis by MALDI). Importantly, the application of MALDI allowed the identification of different sets of peptides and proteins compared to ESI. Furthermore, the system showed to be superior in the identification of certain phosphosites. Easy to handle, great source mirror cleaning option (reduces the interactions with service technicias significantly) and reliable laser."

Review date: 29 Mar 2017 | SCIEX TOF/TOF™ 5800 System
  • Status:

    Expert Reviewer

  • Member since: 2016

  • Organization: Novartis Pharma AG



  • Ease of use
    4 out of 5
    After sales service
    5 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
LC-MALDI-MS as orthogonal technology to LC-ESI-MS
Rating: 4.3

  • Application Area:Large scale proteomics experiments

"The TOF/TOF 5800 System was used in the lab in order to perform LC-MALDI-MS experiments. The system was found to be robust and relatively easy to use. Having a self-cleaning MALDI source helped to significantly decrease the number of interventions by service technicians. LC-MALDI-MS was found to deliver orthogonal information to LC-ESI-MS (e.g. different peptides identified, differences in the identification of phosphorlyation sites). Furthermore, the possibility of "storing" a chromatographic run on a MALDI target plate was extensively used, both for re-analysis of samples but also for new methods of relative protein quantification."

Review date: 28 Feb 2017 | SCIEX TOF/TOF™ 5800 System

The SCIEX TOF/TOFTM 5800 System provides the fastest and most confident path to the identification and relative quantitation of proteins. The systems unmatched speed and sensitivity make it the ideal platform for biomarker discovery, MALDI mass spectrometry imaging, and protein identification.

Features of the TOF/TOFTM 5800 System:

  • More than 10X faster data acquisition with new 1KHz laser and DynamicExitTM algorithm
  • Unique OPtiBeamTM on-axis laser irradiation increases sensitivity in both MS and MS/MS modes by 10x over systems without an on-axis laser
  • Maximum up-time and throughput by continuously heating of the source mirror and user programmable source mirror cleaning
  • Improved resolution with new reflectron mirror design and 1000 MHz digitizer
  • High-resolution precursor ion selection with novel timed-ion selector

Product Overview

SCIEX TOF/TOF™ 5800 System by SCIEX product image

SCIEX TOF/TOF™ 5800 System

Manufacturer SCIEX

4.6 / 5.0 | 4 reviews