Status:
ReviewerMember since: 2024
Organization: Envu
Solid instrument
Application Area: Analysis of pesticide products
"Great product and really easy to use. The Agilent 1290 HPLC/DAD is a solid instrument for the analysis of pesticide formulations. High accuracy and good reproducibility. The autosampler did break early into the use of the instrument, but Agilent came and fixed it quickly."
Status:
Advanced ReviewerMember since: 2022
Organization: Sanofi
Excellent densitivity
Application Area:Biopharma
"Best of its class detector with excellent sensitivity and spectrum quality"
Status:
ReviewerMember since: 2021
Organization: Food and Drug Administration
Highly efficient and user friendly.
Application Area:Physico chemical analysis on pharmaceutical products
"High quality, fast and reliable results. Prompt action of service engineers."
Status:
ReviewerMember since: 2019
Organization: Recipharm
"Plug-and-play" services and system.
Application Area:Pharmaceuticals in liquid, not heavy matrix
"Agilent's service when installing a new UPLC is very professional and quick. IQ/OQ were done very quickly without any problems. The UPLC is easy-to-use and can be called a "plug-and-play" system"
Status:
ReviewerMember since: 2020
Organization: Politechnika Slaska
A very good chromatograph that should be the basic equipment for every laboratory.
Application Area:Determination of industrial additives in water
"I've been working with this chromatograph for less than a year. Its main advantages include ease of use, a very simple way of exchanging columns, access to all chromatograph components, and long service life of the DAD detector. The Infinity Diode ArrayDetector G1315C works in the wavelength range 190-640nm. The matrix contains 1024 diodes. The slit width is programmable in the range of 1, 2, 4, 8, nm; the programming of the slit width facilitates the optimization of the performance in terms of sensitivity (S / N) and spectral resolution. The pump produces a maximum pressure of 1300 bar (in the flow range up to 2 ml/min) and 800 bar at a flow of 5 ml/min. The 4-channel vacuum degasser is integrated with the pump. The only problem for me is the software, which is not always intuitive. I have also been working on gas chromatographs by Agilent Technologies for many years and the software has never been a problem for me. I find this equipment very functional and I cannot imagine my daily work without it."
Status:
ReviewerMember since: 2020
Organization: novartis
Easy to use.
Application Area:Pharmaceutical analyses
"It is easy to use and is time saving. It consumes less solvent and takes less time to run the analysis than other systems."
Status:
ReviewerMember since: 2019
Organization: King khalid University
Great instrument reliable and easy to use.
Application Area:QC of food matrix, drug development study, metabolomics
"It is easy to use and currently in use for drug method development, food metabolomics and drug pharmokinetics studies. I highly recommend this to other scientist if it fits in your budget."
The 1290 Infinity II Diode Array Detector (DAD) delivers multiple wavelength detection with full spectra at sampling rates up to 240 Hz for ultrafast UHPLC separations. The Max-Light cartridge cell features optofluidic waveguides, which improve light transmission to near 100% efficiency without sacrificing resolution caused by cell dispersions effects. With typical noise levels of ±0.6 µAU/cm, the 60 mm path length flow cell gives up to 10 times higher sensitivity than detectors with conventional flow cells.
Any compromising refractive index and thermal effects are almost entirely eliminated, resulting in significantly less baseline drift for more reliable and precise peak integration.
Features: